Readymade Industrial RO Plants RO SYSTEM CONFIGURATION 1. RO membrane and stainless steel membrane housing 2. Stainless steel frame 3. Security filter system 4. Booster pump (horizontal or vertical mode) 5. Low-pressure protection switch 6. Solenoid protection switch 7. Clean water flow meter and drain water flow meter 8. Digital controller 9. CM-230 total dissolved solid meter 10. Feed water pressure gauge 11. Pre-membrane pressure gauge 12. Drain water pressure gauge
|
Model Item
|
800GPD
|
1500GPD
|
3000GPD
|
6000GPD
|
|
Min. supply water flow capacity
|
0.27T/H
|
0.5T/H
|
1T/H
|
2T/H
|
|
Min. source water pressure
|
40PSI
|
40PSI
|
40PSI
|
40PSI
|
|
Water temperature
|
5~45 C
|
|
PH
|
3~10
|
|
Rigidity
|
17 mg/L (according to CaCO3)
|
|
Turbidity degree
|
NTU<1
|
|
Max. Mud Index
|
SDI<5
|
|
TDS
|
TDS<1000ppm
|
|
Ferric content
|
<0.1mg/L
|
|
Oxygen concentration
|
0.1mg/L
|
|
Manganese content
|
0.5mg/L
|
|
Organic compound
|
1mg/L
|
|